    France P8G-2B Series Neon Transformers

    P8G-2B Features
    Easy access terminals
    Service switch
    Top visible diagnostic LED
    Pre-wired primary leads
    Carry handle
    UL compliant stepped base plate



    Ease of Installation - Patented angled bushings for greater visibility and ease of access to electrical connections, LED, and service button. Does not block mounting screws and the step plate eliminates double-nutting.
    Built-in carrying handle
    Primary wiring requirements of a non-SGFI transformer - With the added safety of a Secondary
    Ground Fault Protection with simple wire nut connections.
    User friendly - Adapts to most grounding situations.
    Easy wiring methods - Virtual midpoint and series wiring methods.
    Secondary Circuit Ground Fault Protection - (SGFP) Disables unit upon detection of arcs to
    ground in compliance with UL2161, C22.2 No. 255, and NEC requirements.
    Visible advanced diagnostic LED - Faster, easier troubleshooting is provided by an intelligent circuit that detects both primary and secondary faults and communicates the cause of the fault using the on -board LED.
    Auto reset - After secondary ground fault, automatically attempts to reset three times within ten seconds.  Manual reset possible any time by disconnecting and reconnecting primary power.
    Last Fault Recall - Allows service technician to retrieve the last fault experienced, even after the fault condition has been cleard.
    Bypass feature - For easy troubleshooting of ground faults, overrides the SGFP feature for up to 30 minutes.